OSHA 1910.28(B)(9) CAGED LADDER UPDATE

1910.28(b)(9)(i): For fixed ladders that extend more than 24 feet (7.3 m) above a lower level, the employer must ensure:

Before 2017

Fixed ladders over 20ft

Required to have a cage, well, ladder safety system, or PFAS

Cages were mandatory for ladders over 20ft

2017 OSHA Ruling

(New Ladders After Nov. 18, 2018)

1910.28(b)(9)(i)(B): New fixed ladders. Each fixed ladder installed on and after November 19, 2018, is equipped with a personal fall arrest system or a ladder safety system.

Fixed ladders over 24ft, installed after Nov. 18, 2018

Must have PFAS or a ladder safety system; cages alone are not compliant

Cages alone no longer meet OSHA requirements for fall protection

2017 OSHA Ruling

(Existing Ladders Before Nov. 19, 2018)

1910.28(b)(9)(i)(A): Existing fixed ladders. Each fixed ladder installed before November 19, 2018 is equipped with a personal fall arrest system, ladder safety system, cage, or well.

Fixed Ladders over 24ft, installed before Nov. 19, 2018

Cages are grandfathered in until 2036, but must eventually have a PFAS or ladder safety system

Cages allowed temporarily, but must be phased out by 2036

2036 OSHA Deadline

1910.28(b)(9)(i)(D): Final deadline. On and after November 18, 2036, all fixed ladders are equipped with a personal fall arrest system or a ladder safety system.

All fixed ladders over 24ft

Must have PFAS or ladder safety system; cages alone are not compliant

Cages must be removed or supplemented* with a PFAS or ladder safety system

*1910.28(b)(9)(iv): The employer may use a cage or well in combination with a personal fall arrest system or ladder safety system provided that the cage or well does not interfere with the operation of the system.